PNNSbreadcrumb separatorProtocol Specification Allocationbreadcrumb separatorETSI Experimental Result Codes

List of Diameter Experimental Result Codes allocated by ETSI

Diameter Experimental Result Codes are allocated according to the recommendations in RFC 3588, i.e. in the following groups:

  • - 1xxx (Informational)
  • - 2xxx (Success)
  • - 3xxx (Protocol Errors)
  • - 4xxx (Transient Failures)
  • - 5xxx (Permanent Failures)

ETSI generally allocates a block of 20 Experimental Result Codes to each specification in which these codes are specified.

The following are the ETSI Experimental Result Codes, to be used with the ETSI enterprise number (13019) as the Vendor-ID in the Experimental Result AVP.

Informational result codes

The Informational result codes shall use the values from 1001 to 1999 in the Experimental-Result-Code AVP.

No informational result codes have yet been allocated by ETSI.

Success result codes

The Success result codes shall use the values from 2001 to 2999 in the Experimental-Result-Code AVP.

No success result codes have yet been allocated by ETSI.

Transient Failure result codes

The Transient Failure result codes shall use the values from 4001 to 4999 in the Experimental-Result-Code AVP. The reserved ETSI specific Transient Failure result codes are presented in the following table.

Experimental Result Code  Result text  Specified in ETSI Specification 
 4001  DIAMETER_SYSTEM_UNAVAILABLE  ES 283 034
 4002-4020  Reserved for future use in ES 283 034
 4021  Reserved for future use in TS 183 187  TS 183 017
 4022-4040  Reserved for future use in TS 183 187
 4041  INSUFFICIENT_RESOURCES  ES 283 026
 4042  Reserved for use in ES 283 026
 4043  COMMIT_FAILURE
 4044  REFRESH_FAILURE
 4045  QOS_PROFILE_FAILURE
 4046  ACCESS_PROFILE_FAILURE
 4047  PRIORITY_NOT_GRANTED
 4048-4060  Reserved for future use in ES 283 026
 4061  NETWORK_RESOURCE_UNAVAILABLE  TS 183 071
 4062  NETWORK_RESOURCE_INSUFFICIENT
 4063-4080  Reserved for future use in ES 183 071

Permanent Failure result codes

The Permanent Failure result codes shall use the values from 5001 to 5999 in the Experimental-Result-Code AVP. The reserved ETSI specific Permanent Failure result codes are presented in the following table.

Experimental Result Code  Result text  Specified in ETSI Specification 
 5001  Reserved for future use in ES 283 034  ES 283 034
 5002-5020  Reserved for future use in ES 283 034
 5021  BINDING_FAILURE  TS 183 017
 5022-5040  Reserved for future use in TS 183 017
 5041  MODIFICATION_FAILURE  ES 283 026
 5042-5060  Reserved for future use in ES 283 026
 5061-5080  Reserved for future use in TS 183 060  TS 183 060
 5081-5100  Reserved for future use in TS 183 071  TS 183 071